Victron LiFePO4 battery 12,8V/100Ah – Smart

A Victron LiFePO4 battery 12,8V/100Ah consists of 4 cells connected in series and has a built-in cell monitor.

Available on backorder

  ... people are viewing this right now

  Share

Victron LiFePO4 battery 12,8V/100Ah – Smart

The Victron LiFePO4O Lithium Iron Phosphate (LiFePO4 or LFP) Battery is the safest of the main types of lithium ion batteries. The nominal voltage of an LFP cell is 3,2V (lead-acid batteries: 2V/cell). Therefore, a battery LFP 12,8 V consists of 4 elements connected in series. and a 25,6V battery consists of 8 cells connected in series.

The Victron LFP battery does not need to be fully charged. Lifetime is even slightly improved on a partial charge instead of a full charge. This is a major advantage of LFP compared to lead-acid. Other advantages are wide operating temperature range, excellent cycling performance, low internal resistance and high efficiency.

Advantages of the Victron LiFePO4 battery 12,8V/100Ah – Smart

  • Absolutely safe (no risk of ignition, no fumes)
  • Long life: Over 2-2500 full charge discharge cycles. For photovoltaics, it can exceed 5000 cycles, depending on the use.
  • High charging speed (0.3 to 1C), This means that charging can be done during the day, not only at night.
  • Minimal losses during charging / discharging
  • Compared to lead batteries, it has half the volume and 1/3 the weight.
  • Protected by BMS from over-charging or over-discharging, which means that we take advantage of all the stored energy, without damaging the battery
  • Nominal cost per stored AA about the same as Lead acid batteries. But if we take into account the technical limitations of lead batteries, the actual cost is much lower. In other words, considering all parameters, it is the most economical solution.

Efficiency
In many applications (especially off-grid solar and/or wind), energy efficiency can be critical. The round trip energy efficiency of an LFP battery is 92%. The charging process of lead-acid batteries becomes particularly inefficient when the 80% state of charge is reached, resulting in 50% efficiency or even less in solar systems where several days of backup power are required (battery operating at 70% to 100% charged state ). In contrast, an LFP battery will still achieve 90% efficiency under shallow discharge conditions.

Cell balancing and monitoring

LFP batteries have built-in balancing and cell monitoring. Up to 5 batteries can be paralleled and up to four 12V batteries or two 24V batteries can be connected in series so that a 48V battery pack of up to 1500Ah can be assembled. Cell balancing/monitoring cables can and must be connected to a battery management system (BMS).
Bluetooth app available to monitor cell voltage and temperature.

Battery Management System (BMS)
The BMS:
1.It generates an alarm whenever the voltage of a battery cell drops below 3,1V (2,85-3,15V adjustable).
2. Disconnects or turns off the load whenever the voltage of a battery drops below 2,8V (adjustable 2,6V-2,8V).
3. Stops the charging process whenever the voltage of a battery cell rises to more than 4,2V.
4. Shuts down the system whenever the temperature of a cell exceeds 50°C.

Requires one of these BMS:

  • VE.Bus BMS – recommended for systems with our inverter/chargers.
  • Victron miniBMS – recommended for use in small systems.
  • BMS 12/200 Battery Management System – recommended for use in automotive and marine systems with DC loads and alternators.
  • Smart BMS CL 12/100 – recommended for use in automotive and marine systems with DC loads and alternators.

 

Specifications

Battery specifications
 

VOLTAGE AND CAPACITY

LFP-

Smart 12,8/50

LFP-

Smart 12,8/60

LFP-

Smart 12,8/100

LFP-

Smart 12,8/160

LFP-

Smart 12,8/200

LFP-

Smart 12,8/300

LFP-

Smart 25,6/200

Nominal voltage 12,8V 12,8V 12,8V 12,8V 12,8V 12,8V 25,6V
Nominal capacity @ 25°C* 50Ah 60Ah 100Ah 160Ah 200Ah 300Ah 200Ah
Nominal capacity @ 0°C* 40Ah 48Ah 80Ah 130Ah 160Ah 240Ah 160Ah
Nominal capacity @ -20°C* 25Ah 30Ah 50Ah 80Ah 100Ah 150Ah 100Ah
Nominal energy @ 25°C* 640Wh 768Wh 1280Wh 2048Wh 2560Wh 3840Wh 5120Wh
*Discharge current ≤1C
CYCLE LIFE (capacity ≥ 80% of nominal)
80% DoD 2500 cycles
70% DoD 3000 cycles
50% DoD 5000 cycles
DISCHARGE
Maximum continuous

discharge current

100A 120A 200A 320A 400A 600A 400A
Recommended continuous

discharge current

≤50A ≤60A ≤100A ≤160A ≤200A ≤300A ≤200A
End of discharge voltage 11,2V 11,2V 11,2V 11,2V 11,2V 11,2V 22,4V
OPERATING CONDITIONS
Operating temperature Discharge: -20°C to +50°C Charge: +5°C to +50°C
Storage temperature -45 ° C to + 70 ° C
Humidity (non-condensing) Max. 95%
Protection class IP 22
CHARGED
Charge voltage Between 14V/28V and 14,4V/28,8V (14,2V/28,4V recommended)
Float voltage 13,5V / 27V
Maximum charge current 100A 120A 200A 320A 400A 600A 400A
Recommended charge

current

≤30A ≤30A ≤50A ≤80A ≤100A ≤150A ≤100A
OTHER
Max storage time @ 25°C* 1 year
BMS connection Male + female cable with M8 circular connector, length 50cm
Power connection (threaded

inserts)

M8 M8 M8 M8 M8 M10 M8
Dimensions (hxwxd) mm 199 x 188 x 147 239 x 286 x132 197 x 321 x 152 237 x 321 x 152 237 x 321 x 152 347 x 425 x 274 317 x 631 x 208
Weight 7kg 12kg 15kg 20kg 22kg 51kg 56kg
*When fully charged
Weight 3 kg

Most viewed products

Recently viewed products

Victron battery, lithium, LiFePO4 battery 12,8V/100Ah - Smart,

Victron battery, lithium, LiFePO4 battery 12,8V/100Ah - Smart,

A Victron LiFePO4 battery 12,8V/100Ah consists of 4 cells connected in series and has a built-in cell monitor.

My cart
Close Wishlist
Close Recently Viewed
Compare Products (0 Products)
Compare Products
Compare Products
Compare Products
Compare Products
Category