MultiPlus 12/1200 / 50-16

726.00 
619.00  Excluding VAT
767.56  Includes VAT

The main output operates as an uninterruptible power supply. MultiPlus takes over the power supply of the connected loads in case of failure of the network or when the main power supply / generator is disconnected. This happens almost instantly (in less than 20 milliseconds) so that computers and other electronic devices can continue to run without interruption.

Available on backorder

  ... people are viewing this right now

  Share

Two AC outputs

The main output operates as an uninterruptible power supply. MultiPlus takes over the power supply connected to it

in case of mains failure or when the main power supply / generator is disconnected. This happens almost instantly (in less than 20

milliseconds) so that computers and other electronic devices can continue to operate without interruption.

The second output is only active when the main AC power supply is available on one of the MultiPlus inputs. In this way, loads that should not be supplied by the battery in an emergency, such as e.g. a water heater, can be connected to this output (the second output is only available on power models 3 kVA and above).

Almost unlimited power thanks to the parallel operation

Up to 6 Multis can operate in parallel to achieve higher power efficiency. Six units 24/5000/120 for

for example, they can provide an output power of 25 kW / 30 kVA with a charging capacity of 720 Amps.

Possibility of three-phase supply

In addition to the parallel connection, three units of the same model can be combined to provide a three-phase supply. In

In case a lot of power is required, the possibility of parallelism of up to 6 groups of three units, can give

combined a giant inverter up to 75 kW / 90 kVA with a charging capacity greater than 2000 Amps.

PowerControl - Control the power supply

MultiPlus is a very powerful battery charger. Therefore, it can draw a very large current from it

generator or power supply side (approximately 10 A per 5 kVA at 230 VAC). With the Multi control panel, you can

set the maximum current that the device can draw from the generator or mains. MultiPlus after taking into account the loads

on the AC side, will give excess power to charge the batteries, thus preventing the generator or

electrical network to which it is connected.

PowerAssist - Ability to compensate for the generator or network

This feature is based on Power Control. Allows MultiPlus to support with

power the alternative source to which it is connected, when the latter is in a state of weakness. Because the maximum power

usually only required for a limited time if MultiPlus is found to be deficient in the

generator or mains power supply, can instantly compensate for this shortage from the battery. When the load is reduced, the

Excess energy will be used to recharge the battery.

Solar energy: AC even in case of mains failure

MultiPlus can be used off-grid for autonomy from the electricity grid, as well as on-grid

for connection to it photovoltaic or alternative energy sources. Loss detection software is also available from

network.

System setup

  • -In stand-alone mode and in case settings changes need to be made, this can be done in minutes with a DIP switch setting procedure
  • – Off-grid, grid-interactive and autonomous applications that include grid-coupled inverters and/or MPPT solar chargers are set up with “Assistants” software (special software for specific

    applications).

  • – Arrangements with parallel inverters and three-phase supply are configured through the VE.Bus Quick Configure and VE.Bus System Configurator software.

On-site supervision and operation control

Available modes are: Battery Monitor, Multi Control Panel, Ve.Net Blue Power Panel, Color Control Panel, smartphone or

tablet (Bluetooth Smart), laptop or desktop (with USB or RS232 connection).

Remote monitoring and operation control

  • Available modes are: Victron Ethernet Remote, Victron Global Remote and Color Control Panel.
  • The data can be stored and displayed free of charge on the VRM (Victron Remote Management) website.

Remote configuration

When the device is connected via Ethernet, you can access and change the settings remotely on the systems

with color control panel (Color Control Panel).

specifications

  • Power (W): 1000
  • Input Voltage (V): 12V DC / 230V AC
  • Output Voltage (V): 230 AC
  • Efficiency (%): 93
  • IP protection: IP21
  • Warranty (years): 5
Weight 8.2 kg
Brand

Most viewed products

Recently viewed products

  • -19%Limited
    Goodwe GW25K-MT 220V-inverter-diktyou-net-metering, prices, offers, purchase, net metering PPC, HEDNO
    Goodwe GW25K-MT 220V mains inverter 2,778.00 
    2,239.00  Excluding VAT
    2,776.36  Includes VAT

    Goodwe GW25K-MT 220V network inverter for interconnected net metering systems

    Available on backorder

  • -19%Limited
    Victron 12V/200Ah AGM Telecom Battery (M8), Vehicles, Boats
    Battery Victron 12V/200Ah AGM Telecom (M8) 572.00 
    462.81  Excluding VAT
    573.88  Includes VAT

    Battery Victron 12V/200Ah AGM Telecom (M8)

    Victron 12V/200Ah AGM Telecom battery (M8) designed for telecommunication applications. Excellent "space saver" for marine and vehicle applications.

    Available on backorder

  • -27%Limited
    WHOLESALE PRICE 2v RES 6-SOPzS 965AH / C120 deep discharge batteries SUNLIGHT
    6 SOPZS 965AH / C120 2V RES Open type Sunlight battery 274.00 
    199.00  Excluding VAT
    246.76  Includes VAT

    The 2v batteries RES 6-SOPzS 965AH / C120  Sunlight, Greek-made deep discharge company are an economical and reliable solution for energy storage in small and medium autonomous PV systems. The maximum service life according to the manufacturer's specifications is 15 years (Design Life under Float Conditions)

    SOPzS batteries are deep discharge with cylindrical lead plates and with 2500 life cycles at 50% discharge (DOD).

    They are made of translucent durable housing, for easy monitoring of the liquid level and quite resistant to repeated loading-unloading.

    Capacity:

    969Ah / C120

    Dimensions: 198mm x 137mm x 613mm (Height 640 mm with poles)

    Price without VAT.

    In stock

  • -47%LimitedSOLD OUT
    290 watts - 295 watts photovoltaic panel European
    290 -295 watt Photovoltaic panel European 178.00 
    95.00  Excluding VAT
    117.80  Includes VAT

    290 watts - 295 watts photovoltaic panel European

    Out of stock

  • -11%Limited
    50A digital solar charge regulator with Liquid crystal display for photovoltaic panels up to 750 watts / 12v or up to 1500watt / 24v Polycrystalline
    50A digital charging regulator with LCD & usb screen 89.00 
    79.00  Excluding VAT
    97.96  Includes VAT

    50A digital solar charge regulator with Liquid crystal display for photovoltaic panels up to 750 watts / 12v or up to 1500watt / 24v Polycrystalline

    In stock

  • -27%LimitedSOLD OUT
    Semi-flexible photovoltaic panel 150 watt INVICTUS SRF-150
    Semi-flexible photovoltaic panel 150 watt INVICTUS SRF-150 299.00 
    219.00  Excluding VAT
    271.56  Includes VAT

    Semi-flexible photovoltaic panel 150 watt INVICTUS SRF-150

    Flexible photovoltaic panels - frames Semi-flexible photovoltaic panels 150 watt INVICTUS SRF-150 make them suitable for use in: yachts / yachts sailing boats, prefabricated houses, camping accommodation

    Out of stock

  • -27%LimitedSOLD OUT
    2v ecopvv 1500 gel batteries
    BATTERY 2V GEL deep discharge 10 ECOPVV 1500 / 1580Ah C100 685.00 
    499.00  Excluding VAT
    618.76  Includes VAT

    BATTERY 2V GEL deep discharge 10 ECOPVV 1500 / 1580Ah C100

    The enhanced range of deep discharge batteries GEL 10 ECOPVV 1500 / 1580Ah 2V C100 (Type OPzV ), GEL technology provides truly excellent performance and long life. The double element  10 ECOPVV 1500 / 1580Ah 2V C100  as an accumulator can approach voltage float services even 20 years of life.

    The batteries  10 ECOPVV 1500 / 1580Ah 2V C100 They are manufactured according to the high German quality standards and are suitable for deep discharges and stresses in extreme operating conditions. They offer up to 3.500 cycles with a discharge rate of 50%.
    It is an excellent choice in terms of price, quality and performance in relation to the competition.

     

    1580Ah C100 / 3500 charge cycles at 50% of discharge

    Dealership Warranty 2 years

    Price without VAT

    Out of stock

  • -15%Limited
    Solar Energy + 3 SMA inverters-10kw 10,800.00 
    9,200.00  Excluding VAT
    11,408.00  Includes VAT

    Solar Energy plus SE 250 -255 WATT 10kw with photovoltaic panels of monocrystalline silicon. Pieces 40 with a total power of 10000 watts

    The set is accompanied by

    SMA inverters 2 Items Sunny Boy 3000 TL-20 & 1 piece SMA Sunny Boy 4000 TL-20. Total power 11.000 wp

     Significant advantage for the operation of the photovoltaic system even in case of failure of one of the three phases or in case of material failure (inverter) which if a three-phase inverter is selected puts the entire PV system out of operation with significant loss of revenue until its replacement .

     Price without VAT

    Available on backorder

  • -44%LimitedSOLD OUT
    Battery Gel 150AH (Asian markets) 425.00 
    239.00  Excluding VAT
    296.36  Includes VAT

    150AH 12V GEL closed type deep discharge with a lifespan of 10-12 years.

    Price without VAT

     

    Out of stock

  • -19%Limited
    Mppt 3210A 30A 780 watt charge regulator 119.30 
    97.00  Excluding VAT
    120.28  Includes VAT

    Charging regulator MPPT 30A tracer 3215A with Digital Display model 2016. Maximum power 780 WATT in 24v PV panel

    Tracer-A series is based on common positive design and advanced MPPT control algorithm, with LCD displaying running status, this product is artistic, economical and practical.

      With MPPT control algorithm, in any situation, products of this series can quickly and accurately track out the best maximum power point (MPP) of photovoltaic array, in order to obtain the maximum solar energy in time, which remarkably improves energy efficiency. There is dual display function: local LCD panel or remote meter (needs extra MT50). With Modbus communication protocol interface, it is convenient for customers to expand applications and monitor in various fields like telecommunication base station, household system, street lighting system, wilderness monitoring system, etc.

      All-round electronic fault self-test function and enhanced electronic protection function could further avoid damages on system components resulting from installation errors or system failures.

     Price without VAT

    In stock

MultiPlus 12/1200/50-16,

MultiPlus 12/1200/50-16,

Get the Victron MultiPlus 12/1200 / 50-16 pure sine wave inverter for your photovoltaic-wind turbine, caravan or boat at your best - lowest price on the market.

My cart
Close Wishlist
Close Recently Viewed
Compare Products (0 Products)
Compare Products
Compare Products
Compare Products
Compare Products
Category