Number of MPP trackers | 1 |
---|---|
Max. input current (Idc max_inverter)
|
A 175 |
DC input voltage range (Umin dc - Udc-max)
|
580 - 1000 V |
Feed-in start voltage (Udc-start)
|
650 V |
MPP voltage range (Umin mpp - Umpp max)
|
580 - 930 V |
Max. PV power generator (Pdc-max)
|
150 kWpeak |
Max. input current PV1 (Idc max, PV1)
|
A 100 |
Max. input current PV2 (Idc max, PV2)
|
A 100 |
Max. short-circuit current PV1 (Isc max, PV1)
|
A 125 |
Max. short-circuit current PV2 (Isc max, PV2)
|
A 125 |
Max. short-circuit current inverter (Isc max, inverter)
|
A 250 |
Max. power PV system PV1 (Pdc max, PV1)
|
79 kWpeak |
Max. power PV system PV2 (Pdc max, PV2)
|
79 kWpeak |
Number of DC connections PV1 | 1 |
Number of DC connections PV2 | 1 |
Max. AC fuse size rating | A 355 |
AC nominal output (Pac, r)
|
100 kW |
---|---|
Max. output power (Pac max)
|
100 kVA |
AC output current (Iac name)
|
151,5A at 220Vac, 144,9A at 230Vac |
Grid connection (Uac, r)
|
3 ~ NPE 380/220, 3 ~ NPE 400/230 V |
AC voltage range (Umin - UMax)
|
180 - 270 V |
Frequency (fr)
|
50 / 60 Hz |
Frequency range (fmin - fMax)
|
45 - 65 Hz |
Total harmonic distortion | <3,0% |
Power factor (cos fac, r)
|
0 - 1 ind, / cap, |
Width
|
1109 mm |
---|---|
Height
|
755 mm |
Depth
|
346 mm |
Weight | 103 kg |
Weight incl. packaging | 121 kg |
Degree of protection | IP65 |
Protection class | 1 |
Overvoltage category (DC / AC) 1)
|
2 / 3 |
Night-time consumption | 15w |
Installation | Indoors and outdoors 4) |
Ambient temperature range | -40 ° C - + 65 ° C (optional AC-disconnect: from - 30 to + 65 ° C) |
Allowed humidity | 0 - 100% |
Max. altitude 2)
|
4000 |
Certificates and compliance with standards | VDE-AR-N 4105, VDE-AR-N 4110, IEC 62109-1 / -2, IEC 62116, IEC 61727 R25, AS / NZS 4777, CEI 0-16, CEI 0-21, EN 50549-1 / - 2, VDE 0126-1-1 * |
Inverter topology | Transformerless |
cooling | Active cooling technology and double wall system |
Interference emission class | B |
Max. efficiency (PV - grid) | 98,5% |
---|---|
European efficiency (the EU) | 98,2 / 97,7 / 97,3 (580Vdc / 800Vdc / 930Vdc) |
the at 5% Pac, r 3)
|
95,57 / 90,89 / 89,19 (580Vdc / 800Vdc / 930Vdc) |
the at 10% Pac, r 3)
|
97,32 / 95,55 / 93,75 (580Vdc / 800Vdc / 930Vdc) |
the at 20% Pac, r 3)
|
98,23 / 97,39 / 96,79 (580Vdc / 800Vdc / 930Vdc) |
the at 25% Pac, r 3)
|
98,33 / 97,70 / 97,27 (580Vdc / 800Vdc / 930Vdc) |
the at 30% Pac, r 3)
|
98,44 / 97,91 / 97,54 (580Vdc / 800Vdc / 930Vdc) |
the at 50% Pac, r 3)
|
98,49 / 98,19 / 98,02 (580Vdc / 800Vdc / 930Vdc) |
the at 75% Pac, r 3)
|
98,38 / 98,19 / 98,05 (580Vdc / 800Vdc / 930Vdc) |
the at 100% Pac, r 3)
|
98,21 / 98,05 / 97,91 (580Vdc / 800Vdc / 930Vdc) |
MPP adaptation efficiency | 99,9 |
DC insulation measurement | Included |
---|---|
Overload behavior | Operating point shift. Power limitation 5) |
DC disconnector | Included |
DC reverse polarity protection | Included |
Integral RCMU | Included |
Overvoltage protection devices | Type 1 + 2 integrated, Type 2 optional 6) |
6x digital in / out + 6x digital in | Programmable interface for ripple control receiver, energy management, load control Inputs: Voltage level low: min. 0V - max. 1.8V; high: min. 4,5V - max. 28,8V / Input resistance: 70kOhm Outputs: 5 Watt @ 12V in total for all six digital outputs when supplied internally in case of no load on the USB Port. 1A @> 12,5V to 24V per digital output when supplied externally by an external power supply but in total max. 3A integrated |
---|---|
Emergency stop (WSD) | Yes |
Data logger and web server | Included 7) |
WiFi | Fronius Solar.web, Modus TCP Sunspec, Fronius Solar API (JSON) 7) |
2x RS485 | Modbus RTU Sunspec |
USB (type A socket) | 1 A supply |
Ethernet LAN RJ45 | 10 / 100Mbit; max. 100m Fronius Solar.web, Modbus TCP Sunspec, Fronius Solar API (JSON) |
Cable cross section | 70 - 240 mm² |
---|---|
Conductor material | Al? Cu |
Connection terminals | Cable lug or V clamps |
Single core option (single core cable) | Cable gland: 5 x M40 (10 - 28 mm) |
Multi core option (multi core cable) | Cable gland: 1 x multi core connection Ø 16 - 61.4 mm + 1 x M32 (10 - 25 mm) |
AC Daisy Chaining option (single core cable) | Cable gland: 10 x M32 (10 - 25 mm) |
Cable cross section | 25 - 95 mm² |
---|---|
Conductor material | Al? Cu |
Connection terminals | Cable lug or V clamps, Cable gland: 6 x M40 |
How does saving money on your home with a Fronius network inverter save you money?
Photovoltaic panels are a great way to generate clean energy and reduce electricity bills. They can save you money on your electricity bill by producing clean, clean energy that is not only cheaper than you pay now, but also better for the environment.
There are many other benefits to solar energy as well. You will never have a power outage because you will generate power yourself. You will also receive free, clean electricity at the end of your system life cycle and it is an investment that will pay off over time because your system will last much longer than a traditional one.
Weight | 1 kg |
---|